Introduction
There
are different loading configurations of a cantilever beam, such as end load,
end moment, uniformly load distribution, intermediate load, and triangular load
distribution. The idea is that due to these loading configuration how the
moment and stress changes along the surface of a cantilever beam. Since going through
all of these situations is a long procedure, an end-load configuration of a
cantilever beam with a rectangular cross-section is chosen to describe the
variance of moment and stress along the surface and write equations of moment
and stress in this situation.
As has been shown in Figure 1, one end of the
beam is cantilevered and clamped to a support and a load P is applied at the
free end of the beam. A strain gage is also mounted on the surface of the beam
at a distance x from the clamped end of the beam. From this geometry, we can
obtain equations for bending moment and stress at gage location.
where M is the bending moment at
gage location, P is applied load at free end of the beam, L is distance of load
application, and x is distance of gage location from the clamped end of the
beam. The stress on the surface of the beam at gage location can be calculated
from the following equation:
By combing equations (1) and (2),
we can obtain stress as function of load and geometry.
where E is Young’s Modulus.
Sine the relationship between load,
stress, bending moment, and the geometry have been described in equations (1) through
(6), the purpose of this study was being able to calculate unknown applied
weights at the free end of several cantilever beams by installing strain gages
on the beams’ surfaces in a distance from beams’ clamped ends and evaluate
possibility of any error during this experiment.
Experimental Setup
Two
different types of material made cantilever beams, as shown in Figure 2 , were
used to perform this experiment. The first type beam was made of 2024-T4
aluminum, while the second type beam was made of 6061-T651 aluminum. The
dimensions are shown in Figure 2, but the distances of load application and
strain gages are different for each specimen. The varying dimensions are
tabulated in Table 1. There were a total of seven specimens to be tested. Three
of them were made of 2024-T4 aluminum, and four of them were made of 6061-T651
aluminum. One strain gage was mounted on each cantilever beam in a distance
from the clamped end of the beam. The lead-wires of the strain gage were
connected to a P-3500 strain indicator to read strain at that point.
Experimental Procedure
The
prepared cantilever beam with strain gage was clamped on the edge of a table
and the lead-wires were connected to the strain indicator. An unknown load was
applied on the free end of the beam. The strain at gage location was read by
P-3500 strain indicator after application of the unknown load. Seven specimens
were tested at same manner. The strains for all seven specimens are tabulated
in Table 1.
Data analysis
Theoretical
calculation of stress and strain is presented in equations (4) and (6). By manipulating equation (6), we are able to
calculate unknown weights. Modulus of Elasticity for both types of materials
are used from Module 2 (previous experiment), where the Young’s Modulus was
10.6 Msi for 6061-T651 aluminum and 9.0 Msi for 2024-T4 aluminum beams.
The unknown weights can be
calculated as following:
where
is the indicated
strain on the surface of beam at gage point. E is Young’s Modulus in Msi, b is
beam’s width, t is beam’s thickness, L is the distance of load application on
the beam, and x is the distance of gage from the clamped end. Table 1 also
shows calculation of unknown weights on every beam.
Discussion
The
results show that the calculated values are very close to each others. The
average weight for seven specimens are obtained 5.35 lbs. There may be some
sources of errors, such as, alignment of strain gage, initial zero strain
reading, and Young’s Modulus. Since experimentally mounting strain gages is a
challenging procedure, it is not easy to install all gages along straight line,
or strain gages may be oriented during mounting. This difficulty causes error
in strain indication. Another factor is initial strain of P-3500 which might hasn’t
been set to zero strain before testing. This is also a factor that causes
difference in strain reading from one beam to another. The Young’s Modulus was
obtained from previous experiment. Sine it wasn’t a published value for the
Young’s Modulus to guarantee the accuracy, we can also take this into account
for the source of error.
Conclusion
As
a conclusion, we can say that the results obtained from the experiment are
reasonable. This experiment was an opportunity to get familiar with the theory
of cantilever beams and being able to calculate the stresses and stains along
the surface of a cantilever beam. This experiment also was a tool to obtain an
unknown load at the point of application by using a strain gage on the surface
of a cantilever beam at any point we want to mount.